Accessories for pressure measurement

JUMO offers a variety of accessories for optimum pressure measurement. This includes diaphragm seals and (hygienic) process connections which assist in optimum probe placement. You can also find valves, shut-off valves, and check valves. The JUMO Device App can be found here as well.

  • Product selection guide

Accessories

Filter
1
Hits: 11
Diaphragm seal - With screw-in thread DIN ISO 228/1 or ANSI B 1.201

Diaphragm seal

With screw-in thread DIN ISO 228/1 or ANSI B 1.201 Basic type: 409782
Diaphragm seals protect the pressure measuring device from contaminated, hot, highly viscous, stagnant, crystallizing, and especially corrosive media.
  • Process connection: screw-in thread
  • Nominal widths: 1" NPT, 1.5" NPT, 2" NPT
  • Nominal pressure: max. PN 600
Diaphragm seal - With flange connection according to ANSI B 16.5

Diaphragm seal

With flange connection according to ANSI B 16.5 Basic type: 409786
Diaphragm seals protect the pressure measuring device from contaminated, hot, highly viscous, stagnant, crystallizing, and especially corrosive media. This product has been designed according to ANSI B 16.5 and is available with a sealing strip type RF.
  • Process connection: flange according to ANSI B16.5
  • Nominal widths: DN 2", DN 3", DN 4"
  • Nominal pressure: PN 150 to PN 2500
Diaphragm seal - With membrane 4MDV-10

Diaphragm seal

With membrane 4MDV-10 Basic type: 409780
Diaphragm seals protect the pressure measuring device from contaminated, hot, highly viscous, stagnant, crystallizing, and especially corrosive media.
  • Process connection: flange DIN EN 1092-1
  • Nominal widths: DN 15, DN 20, DN 25, DN 50
  • Nominal pressure PN 40, PN 100, PN 250
Diaphragm seal - With ISS/SMS/RJT socket and union nut

Diaphragm seal

With ISS/SMS/RJT socket and union nut Basic type: 409778
Diaphragm seals protect the pressure measuring device from contaminated, hot, highly viscous, stagnant, crystallizing, and especially corrosive media.
  • Process connection: ISS, SMS, RJT socket
  • Nominal widths: DN 1", DN 1.5", DN 2"
  • Nominal pressure: max. PN 40
Diaphragm seal - With DRD flange or VARIVENT® socket

Diaphragm seal

With DRD flange or VARIVENT® socket Basic type: 409776
Diaphragm seals protect the pressure measuring device from contaminated, hot, highly viscous, stagnant, crystallizing, and especially corrosive media.
  • Process connection: DRD flange; VARIVENT®
  • Diameter: max. 68 mm
  • Nominal pressure: max. PN 40
Diaphragm seal - With clamp connection

Diaphragm seal

With clamp connection Basic type: 409774
Diaphragm seals protect the pressure measuring device from contaminated, hot, highly viscous, stagnant, crystallizing, and especially corrosive media.
  • Process connection: clamp
  • Nominal widths: DN 1.5" or DN 2"
  • Nominal pressure: max. PN 40
Diaphragm seal - With dairy pipe fitting DIN 11851

Diaphragm seal

With dairy pipe fitting DIN 11851 Basic type: 409772
Diaphragm seals protect the pressure measuring device from contaminated, hot, highly viscous, stagnant, crystallizing, and especially corrosive media.
  • Process connection: dairy pipe fitting
  • Nominal widths: DN 25, DN 32, DN 40, DN 50
  • Nominal pressure: max. PN 40
Diaphragm seal with flange connection - DIN EN 1092-1 with sealing strip type B1

Diaphragm seal with flange connection

DIN EN 1092-1 with sealing strip type B1 Basic type: 409784
Diaphragm seals protect the pressure measuring device from contaminated, hot, highly viscous, stagnant, crystallizing, and especially corrosive media. This product has been designed according to DIN EN 1092-1 and is available with a sealing strip type B1.
  • Accessories: stainless steel flushing ring (1.4571)
  • Nominal pressure: PN 16 to PN 400
  • Process connection: DN 25, DN 50, DN 80, DN 100
Valve blocks - for pressure transmitters

Valve blocks

for pressure transmitters Basic type: 409706
Valve blocks can be used in connection with pressure measuring devices. They are used as a shut-off valve and for adjusting the zero point of the pressure measuring device.
  • 2, 3, or 5-valve block
  • PN 420 DN 5
  • Surface: phosphated steel
JUMO PEKA - Hygienic process connection

JUMO PEKA

Hygienic process connection Basic type: 409711
The process connection connects the measuring device with an application-specific process connection adapter. Based on an easy-to-clean design and a cavity-free system, the adapter system is specifically tailored to the requirements of hygienic processes.
  • For temperature, pressure, and conductivity
  • Mounting: can be mounted an unlimited number of times
  • Material: stainless steel 316L
JUMO Device App - Mobile access to JUMO devices

JUMO Device App

Mobile access to JUMO devices Basic type: 709771
The JUMO Device App provides the user with mobile access to their process data at all times. All current process values as well as the alarm and event list from selected JUMO devices which are networked via Ethernet can be viewed in text form.
  • IP address/DNS name
  • Retrieval of event/alarm lists
  • Scan function for device search

item items, maximum number of items reached